Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Densitom ; 24(2): 330-337, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33199190

RESUMO

Bone Strain Index (BSI) is a new finite element analysis tool applied to hip dual energy X-ray absorptiometry scans. The aim of this study was to assess the short-term precision error of BSI on the proximal femur, both on a phantom and patients. The International Society for Clinical Densitometry guidelines were followed for short-term precision error assessment. Dual energy X-ray absorptiometry measurements were performed on an anthropomorphic femur phantom that was scanned twice for 30 times, for a total of 60 scans. For the in vivo part, 30 subjects were scanned twice. BSI precision error was compared to that of bone mineral density (BMD). Both for the phantom and the in vivo study BSI reproducibility was lower compared to that of BMD, as the precision error of BSI resulted 3 times higher compared to that BMD. For phantom measurements, the highest precision value was that of total femur (TF) BMD (coefficient of variation [CoV] = 0.63%, reproducibility = 98.24%), while the lowest precision was the femoral neck (FN) BSI (CoV = 3.08%, reproducibility = 91.48%). Similarly, for the in vivo study, the highest precision was found at TF BMD (CoV = 1.36%, reproducibility = 96.22%), while the lowest value of precision was found for FN BSI (CoV = 4.17%, reproducibility = 88.46%). Reproducibility at TF was always better compared to that of the FN. BSI precision error was about 3 times higher compared to BMD, confirming previous results of lumbar spine BSI. The main source of variability of this new software is related to patient positioning.


Assuntos
Absorciometria de Fóton , Fêmur/diagnóstico por imagem , Análise de Elementos Finitos , Osteoporose/diagnóstico , Software , Absorciometria de Fóton/instrumentação , Absorciometria de Fóton/métodos , Idoso , Densidade Óssea , Feminino , Humanos , Masculino , Osteoporose/metabolismo , Osteoporose/fisiopatologia , Posicionamento do Paciente/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...